Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
China Pharmacy ; (12): 1699-1701, 2016.
Article in Chinese | WPRIM | ID: wpr-501236

ABSTRACT

OBJECTIVE:To establish a method for simultaneous determination of andrographlide and dehydroandrographolide in Ganmaoqing tablet. METHODS:HPLC was performed on the column of Thermo BDS C18 with mobile phase of mathanol-water at a flow rate of 1.0 ml/min,detection wavelength was 225 nm for andrographlide and 254 nm for dehydroandrographolide,col-umn temperature was 30 ℃,and injection volume was 10 μl. RESULTS:The linear range was 2.25-45.00 μg/ml for andrographlide (r=0.9998) and 1.00-20.00 μg/ml for dehydroandrographolid(r=0.9990);RSDs of precision,stability and reproducibility tests were no more than 0.8%;average recoveries were 96.96%-99.80%(n=9) and 96.79%-100.65%(n=9). CONCLUSIONS:The method is simple,accurate and reliable,and can be used for the quality control of andrographlide and dehydroandrographolide in Ganmaoqing tablet.

2.
China Pharmacy ; (12): 3400-3403, 2016.
Article in Chinese | WPRIM | ID: wpr-504934

ABSTRACT

OBJECTIVE:To establish the quality standard of Flemingia philippinensis. METHODS:The properties and micro-scopic characteristics were observed;TLC was adopted for qualitative identification of genistin and genistein;the moisture,total ash and extract were detected;HPLC was adopted for contents determination of genistin and genistein:the column was Thermo BE-TASIL C18 with mobile phase of Acetonitrile-0.5% glacial acetic acid(gradient elution)at a flow rate of 1.0 ml/min,the detection wavelength was 261 nm,column temperature was 25℃,and the injection volume was 10μl. RESULTS:The properties and micro-scopic characteristics of F. philippinensis and F. macrophylla showed strong specificity. TLC spots of genistin and genistein we- re clear and well separated,with no interference in negative control. The moisture was 3.69%-8.37%,total ash was 1.72%-6.74%,and extract was 5.89%-19.65%. The linear range was 0.012 9-2.588 μg for genistin(r=0.999 9)and 0.004 6-0.923 2 μg for genistein (r=0.999 9);RSDs of precision,stability and reproducibility tests were lower than 3.0%;recoveries were 99.63%-101.87%(RSD=0.82%,n=6)and 97.19%-100.34%(RSD=1.23%,n=6). CONCLUSIONS:The method is simple,accurate and specif-ic,and can be used for the quality control of F. philippinensis.

3.
China Pharmacy ; (12)2005.
Article in Chinese | WPRIM | ID: wpr-534132

ABSTRACT

OBJECTIVE: To investigate the effect of detection index of IL-4 and IgE on rapid examination of drug-induced allergic reaction.METHODS: The guinea pigs were injected with drugs intravenously and intraperitoneously,such as normal saline,horse serum,Qingkailing injection,Xiangdan injection,cerebrolysin injection and Chuankezhi injection once a day for 3 days.Then the content of IL-4 and IgE in serum of guinea pigs was recorded at different time points.Allergic reactions of guinea pigs were observed 8 days after intravenous administration,14 days and 21 days after intraperitoneous administration.RESULTS: As compared with normal saline except for Chuankezhi injection,serum level of IL-4 and total IgE were raised obviously before guinea pigs were challenged either in 8 days after intravenous injection of other drugs or in 14 days and 21 days after intraperitoneous injection.Allergic reaction occurred on all those guinea pigs after they were challenged.CONCLUSION: The detection of IL-4 and IgE provides a new way for rapid test of drug-induced allergic reaction.

SELECTION OF CITATIONS
SEARCH DETAIL